The LE-FN-4127 control panel is an analog addressable fire alarm panel containing 2 or 4 SLC loops with each loop supporting 127 devices of any combination (sensors or modules),and 127 analog sounder bases, for a possible total of 254points. Communication between devices is transferred through standard cable (shielded or twisted pair is not required). Each panel includes a 5.25 amp power supply and has 4 on board NAC circuits. An RS-485 bus provides communication to the panel network, while the RS-232 interface allows the convenience of programming via a PC. The system will support a variety of Lifeco devices: photo, ion and heat sensors, which contain a unique, patented sensor design incorporating automatic drift compensation and day/night sensitivity mode. Additional devices include contact monitors, relay controllers, supervised auxiliary output and short circuit isolator modules. In addition, interfaces to conventional detection systems can be established by using a conventional zone monitoring module. The Loop Explorer Windows® Software interface provides the installer with fingertip access to installation programming and diagnostic tools. An Auto-learn feature offers the convenience for quick start applications. Add to this a reputation for high quality and dedicated service makes this an exceptional product both in performance and value.
• Dual RS-485 bus for panel network
• 2 built-in RS-232 interfaces for programming via a PC and serial printer interface
• 5 on board programmable Form C relays rated at 1 amp at 30VDC (Fire1, Fire2, trouble, supervisory, aux.)
• 500mA of auxiliary power available rated at 24 VDC
• Loop Explorer Windows® configuration utility
• *500 network wide software zones
• Network Capability of up to 64 panels
• RS485 slave bus for expansion - up to 31 LEFN-
4127-IO boards or up to 15 LE-FN-LCD-Sserial annunciators and up to16 LE-FN-4127-IO boards
• Auto-learn feature
• Built in help and alarm information screens
• Fire Drill test function
• Walk Test function
• Alarm Verification feature
• FireNET is UL listed for Central Station Service when used with the Bosch D9068 contact dialer
• Operates on 120VAC or 240VAC input voltage
• Powerful & versatile Cause & Effect programming (up to 500 maximum, network wide) including:
*Cause & Effect action
*Disable function configuration
*Test mode configuration
• UL 864 9th edition Listed
• Analog design using Lifeco’s advanced DCP protocol for fast and robust communication
• Up to 127 sensors & modules, plus 127 analog sounder bases, for a total of 254 points possible per loop
• Uses standard wire, no shielded or twisted pair required on SLC loops
• Supports Class B (style 4) and Class A (style 6 or 7) SLC loops
• 4 on board Class B (style Y) NAC circuits rated at 2.5 Amp each
• Programmable sensitivity levels per device & automatic day/night sensitivity modes
• Automatic daily calibration & drift compensation routine
• Large 8-line x 40-character LCD display (320 char.)
• 2 or 4 loop versions (800 addresses/sub-addr. max.)
UL S24976
Primary AC |
120VAC @ 2.1 Amps 60hz Similar Products from Other Suppliers
|